FIRE RESISTANCE AND SMOKE CONTROL TESTS FOR DOOR AND SHUTTER ASSEMBLIES, OPENABLE WINDOWS AND ELEMENTS OF BUILDING HARDWARE - PART 1: FIRE RESISTANCE TEST FOR DOOR AND SHUTTER ASSEMBLIES AND OPENABLE WINDOWS
出版:Association Francaise de Normalisation

专家解读视频
Describes method for determining the fire resistance of door and shutter assemblies and openable windows designed for installation within openings incorporated in vertical separating elements, such as: a. hinged and pivoted doors; b. horizontally sliding and vertically sliding doors including articulated sliding doors and sectional doors; c. folding doors, sliding folding doors /shutters; d. tilting doors; e. rolling shutter doors; f. openable windows; g. operable fabric curtains.
DIN EN 1634-1 : 2014 - Identical
NBN EN 1634-1 : 2014 - Identical
EN 1634-1 : 2014 COR 2018 - Identical
I.S. EN 1634-1:2014 - Identical
UNI EN 1634-1 : 2014 - Identical
EN 1634-1 : 2014 COR 2018 - Identical
BS EN 1634-1 : 2014 - Identical
UNE EN 1634-1 : 2016 - Identical
SN EN 1634-1 : 2014 - Identical