AS/NZS 1660.5.1:1998被替代

Test methods for electric cables, cords and conductors Fire tests - Tests on bunched cables

出版:Standards Australia

获取原文 如何获取原文?问客服 获取原文,即可享受本标准状态变更提醒服务!

专家解读视频

基本信息
标准编号: AS/NZS 1660.5.1:1998
发布时间:1998/1/5 0:00:00
标准类别:Standard
出版单位:Standards Australia
标准页数:20
标准简介

This Standard describes a method of testing to define the ability of bunched cables to restrain flame propagation in defined conditions regardless of their application, i.e. power or telecommunications (including data transmission and optical fibre cables).NOTE: For details of the AS/NZS 1660 series of Standards, see Appendix A.Three categories are defined and distinguished by test duration, and the volume of non-metallic material of the sample under test (see Table 1); they are not necessarily related to different safety levels in actual cable installations. The method of mounting has two designations, F/R and F, where F/R signifies front and rear mounting on the ladder and F signifies front mounting only. Category A has both designations for the method of mounting.NOTE: AS/NZS 1660.5.6 specifies a method of test for combustion propagation characteristics for a single vertical insulated wire or cable. It cannot be assumed that a bunch of similar cables or wires will behave in a similar manner. This is because the propagation of flame along a bunch of cables depends on a number of features, such as -(a) the volume of combustible material exposed to the fire and to any flame which may be produced by the combustion of the cables; (b) the geometrical configuration of the cables and their relationship to an enclosure; (c) the temperature at which it is possible to ignite the gases emitted from the cables; (d) the quantity of combustible gas released from the cables for a given temperature rise; (e) the volume of air passing through the cable installation; and (f) the construction of the cable, e.g. armoured or unarmoured.All of the foregoing assume that the cables are able to be ignited when involved in an external fire.This Standard gives details of a test where a number of cables are bunched together to form various test sample installations. Sections 3, 4 and 5 provide details of different test categories having varying volumes of non-metallic material per metre of the test sample subjected to the test.The method of mounting described as category A, designation F/R, in Section 3 is intended for special cable designs used in particular installations, e.g. power stations.The method of mounting described as category A, designation F, in Section 3 is introduced so that a consistent comparison with Sections 4 and 5 can be made on the effect of increased volume of non-metallic material and test duration.

本标准替代的旧标准

DR 96291

AS 1660.5.1-1993

替代本标准的新标准

AS/NZS 1660.5.1:2005

本标准修订后的版本

AS/NZS 1660.5.1:1998/Amdt 1:2001 -