Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus
出版:International Electrotechnical Committee

专家解读视频
Provides details of the test apparatus to be used for measuring smoke emission when electric or optical fibre cables are burnt under defined conditions, for example, a few cables burnt horizontally. The light transmittance (lt) under flaming combustion and smouldering conditions can be used as a means of comparing different cables or complying with specific requirements. NOTE: For the purposes of this standard, the term ""electric cable"" covers all insulated metallic conductor cables used for the conveyance of energy or signals. The principal changes with respect to the previous edition are as follows: a) closer definition of the draught screen and the chamber orifices; b) closer definition of the support for the cable(s) under test; c) removal of minor differences with equivalent CENELEC work to allow parallel voting with that body. Has the status of a group safety publication in accordance with IEC Guide 1
CEI EN 61034-1 Ed. 2 (2006) - Identical
BS EN 61034-1:2005 - Identical
DIN EN 61034-1 (2006-03) - Identical
VDE 0482-1034-1:2006 - Identical
NF EN 61034-1:2005 - Identical
I.S. EN 61034-1:2005 - Identical
UNE EN 61034-1:2005 - Identical
NEN EN IEC 61034-1:2006 - Identical
PN EN 61034-1:2006 - Identical
AS/NZS 1660.5.2:2006 - Equivalent
OVE/ONORM EN 61034-1:2006 - Identical