Wastewater Lifting Plants For Buildings And Sites - Part 3: Lifting Plants For Limited Applications
出版:Belgian Standards

专家解读视频
This part describes lifting plants for wastewater containing faecal matter for limited applications used for draining a single WC according to EN 33 or EN 37 to which it is directly connected and located below flood level. Plants for limited applications are those where the number of users is small, where there is another WC available above flood level, and the plants serve no more than one wash-hand basin, one shower and one bidet provided by they pass the tests described in clause 8 and they are installed in accordance with EN 12056-1 and no other sanitary appliance is directly or indirectly connected.
I.S. EN 12050-3:2015 - Identical
BS EN 12050-3:2015 - Identical
SS EN 12050-3 Ed. 2 (2015) - Identical
NEN EN 12050-3:2001 - Identical
UNE EN 12050-3:2001 - Identical
NS EN 12050-3 Ed. 1 (2001) - Identical
UNI EN 12050-3:2001 - Identical
NF EN 12050-3:2001 - Identical
ONORM EN 12050-3:2001 - Identical
DIN EN 12050-3 (2001-05) - Identical
SN EN 12050-3:2001 - Identical
EN 12050-3:2015 - Identical
ONORM EN 12050-3:2015 - Identical
UNE EN 12050-3:2015 - Identical
NF EN 12050-3:2015 - Identical
NEN EN 12050-3:2015 - Identical
NS EN 12050-3:2015 - Identical