欢迎来到寰标网! 客服QQ:772084082 加入会员
当前位置: 首页 > 标准详情页

ISO 8529-1:2001现行

Reference neutron radiations Part 1: Characteristics and methods of production

出版:International Organization for Standardization

获取原文 如何获取原文?问客服 获取原文,即可享受本标准状态变更提醒服务!

专家解读视频

基本信息
标准编号: ISO 8529-1:2001
发布时间:2001/2/1 0:00:00
标准类别:Standard
出版单位:International Organization for Standardization
标准页数:24
标准简介

This part of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their responseas a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1 x 10 to the 9th m –2 s –1 , corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv h –1 .This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3.The reference radiations specified are the following:- neutrons from radionuclide sources, including neutrons from sources in a moderator;- neutrons produced by nuclear reactions with charged particles from accelerators;- neutrons from reactors.In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections.- In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron-measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested.- In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices as a function of neutron energy. Since these reference radiations are produced at specialized and well equipped laboratories, only the minimum of experimental detail is given.For the conversion of neutron fluence into the quantities recommended for radiation protection purposes, conversion coefficients have been calculated based on the spectra presented in normative annex A and using the fluence-to-dose-equivalent conversion coefficients as a function of neutron energy as given in ICRP Publication 74and ICRU Report 57.

本标准替代的旧标准

ISO 8529:1989

等同采用的国际标准

GB/T 14055.1-2008 - Identical

KS A ISO 8529-1:2002 - Identical

BS ISO 8529-1:2001 - Identical