欢迎来到寰标网! 客服QQ:772084082 加入会员
当前位置: 首页 > 标准详情页

AS/NZS 2430.3.1:2004部分可行

Classification of hazardous areas Examples of area classification - General

出版:Standards Australia

获取原文 如何获取原文?问客服 获取原文,即可享受本标准状态变更提醒服务!

专家解读视频

基本信息
标准编号: AS/NZS 2430.3.1:2004
发布时间:2004/5/20 0:00:00
标准类别:Standard
出版单位:Standards Australia
标准页数:8
标准简介

This Standard provides examples of area classification and is based on the internationally accepted concept which recognizes the different degrees of probability with which explosive (flammable) concentrations of flammable gas or vapour may arise in installations in terms of both the frequency of occurrence and the probable duration of existence on each occasion. The recommended classifications of this Standard are based on the assumption that plant and equipment are adequately maintained. The Standard is part of a series which recommends the classifications of several commonly occurring situations. NOTE: Appendix A provides methods of classification. This Standard details general matters which must be taken into account when using any other of the AS/NZS 2430.3 series of Standards for the purpose of conducting an area classification. This Standard covers risks due to both fire and explosion. The examples in this Standard may not apply to specific occupancies where— (a) the quantity of release is either very large or very small, in such cases dispersion calculations may be required; (b) the design of a particular plant does not comply with the appropriate Australian or New Zealand Standards; or (c) ventilation, use of inert gases, vapour barriers or other methods, are used to reduce the extent or degree of risk of a particular hazardous area. In all cases classification may be made using the fundamental principles detailed in AS/NZS 60079.10. In general, classifications in accordance with the following codes are acceptable, subject to any additional provisions or modifications as required by the authority: (i) UK IP (Institute of Petroleum), Model Code of Safe Practice for the Petroleum Industry, Part 15: Area Classification Code for Installations Handling Flammable Fluids. (ii) API (American Petroleum Institute) RP 505, Recommended Practice for ‘Classification of Locations for Electrical Installations at Petroleum Facilities classified as Class I, Zone , Zone 1 and Zone 2’. (iii) BS 5908, Code of practice for fire precautions in the chemical and allied industries. Attention is drawn to the fact that an area classified non-hazardous, in accordance with this Standard, may not necessarily be safe in all respects, e.g. toxic and chemical hazards. Unless otherwise specified, the classifications given throughout this Standard are based on the ventilation criteria given in Appendix B.

本标准修订后的版本

AS/NZS 2430.3.1:2004/Amdt 1:2007 -