Rotating Electrical Machines - Part 18-42: Qualification And Acceptance Tests For Partial Discharge Resistant Electrical Insulation Systems (type 2) Used In Rotating Electrical Machines Fed From Voltage Converters
出版:Nederlands Normalisatie Instituut

专家解读视频
Defines criteria for assessing the insulation system of stator/rotor windings of single or polyphase AC machines which are subjected to repetitive impulse voltages, such as pulse width modulation (PWM) converters, and expected to withstand partial discharge activity during service. It also specifies electrical qualification and acceptance tests on representative samples, which verify fitness for operation with voltage-source converters.
IEC/TS 60034-18-42 Ed. 1.0 - Identical