Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests (IEC 61000-4-11:2004+AMD1:2017 CSV)
出版:International Electrotechnical Committee

专家解读视频
IEC 61000-4-11:2004+A1:2017 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This standard applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to 50 Hz or 60 Hz a.c. networks. It does not apply to electrical and electronic equipment for connection to 400 Hz a.c. networks. Tests for these networks will be covered by future IEC standards. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. This second edition cancels and replaces the first edition published in 1994 and its amendment 1 (2000). This second edition constitutes a technical revision in which 1) preferred test values and durations have been added for the different environment classes; 2) the tests for the three-phase systems have been specified. It has the status of a Basic EMC Publication in accordance with IEC Guide 107. The contents of the interpretation sheet 1 of August 2010 have been included in this copy. This consolidated version consists of the second edition (2004) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication.
NF EN 61000-4-11 : 2004 AMD 1 2017 - Identical
BS EN 61000-4-11 : 2004 - Identical
BIS IS 14700-4-11 : 2008(R2015) - Identical
DS EN 61000-4-11 : 2004 AMD 1 2017 - Identical
CEI EN 61000-4-11 : 2006 - Identical
CSA CEI/IEC 61000.4.11 : 2005 - Identical
PN EN 61000-4-11 : 2007 AMD 1 2017 - Identical
DIN EN 61000-4-11: 2019-06 - Identical
SN EN 61000-4-11 : 2004 - Identical
VDE 0847-4-11 : 2005 - Identical
OVE/ONORM EN 61000-4-11 : 2005 - Identical
NEN 11000-4-11 : 1994 - Identical
SANS 61000-4-11 : 1ED 2005(R2010) - Identical
DIN EN 61000-4-11 : 2005 - Identical
NEN EN IEC 61000-4-11 : 2004 AMD 1 2017 - Identical
NBN EN 61000 4-11 : 2005 - Identical
CSA CEI/IEC 61000.4.11 : 2005 - Identical
SANS 61000-4-11 : 1ED 2005(R2010) - Identical
DIN EN 61000-4-11: 2019-06 - Identical
BS EN 61000-4-11 : 2004 - Identical
NF EN 61000-4-11 : 2004 AMD 1 2017 - Identical
OVE/ONORM EN 61000-4-11 : 2005 - Identical
NEN EN IEC 61000-4-11 : 2004 AMD 1 2017 - Identical
EN 61000-4-11 : 2004 AMD 1 2017 - Identical
BIS IS 14700-4-11 : 2008(R2015) - Identical
NBN EN 61000 4-11 : 2005 - Identical
VDE 0847-4-11 : 2005 - Identical
DIN EN 61000-4-11 : 2005 - Identical
DS EN 61000-4-11 : 2004 AMD 1 2017 - Identical
PN EN 61000-4-11 : 2007 AMD 1 2017 - Identical
AS/NZS 61000.4.11:2005 (R2016) - Identical